The GCE medical shut-off valves provide instant shut-off and sectional control of medical gases.
To meet the safety requirements, the gas supply to operating rooms must be equipped with devices that allow for instant shut-off. The GCE medical shut-off valves provide the necessary control by enabling sectional management of the gas supply, ensuring that maintenance can be performed without disturbing the overall system. These medical gas valve units are essential for installation in every main line, riser, and branch line of the pipework system to perform secure maintenance.
To meet the safety requirements, the gas supply to operating rooms must be equipped with devices that allow for instant shut-off. The GCE medical shut-off valves provide the necessary control by enabling sectional management of the gas supply, ensuring that maintenance can be performed without disturbing the overall system. These medical gas valve units are essential for installation in every main line, riser, and branch line of the pipework system to perform secure maintenance.
Ready for Use
Degreased and blown clean, ensuring they are ready for immediate installation.
Flexible Installation
The shut-off valves can be equipped with unions to be soldered to the copper piping for seamless integration.
Leak-Tested
Each medical SOV is individually leak-tested before delivery to guarantee reliability.
High-Quality Seals
The ball is sealed with a washer of PTFE, and the stem is sealed with two silicon O-rings or a PTFE washer for superior durability.
Robust Housing Seals
The medical gas shut-off valve housings are sealed with an EPDM quality O-ring, providing an additional layer of protection.
Maintenance-Free
No maintenance required—the ball valve does not need servicing, and when necessary, the whole valve is exchanged.
Compliance Standards
Complies with Medical Devices Directive 93/42/EEC, EN ISO 7396-1 (Central Gas Supply System), and EN 331 (Manually operated ball valves).
Ready for Use
Degreased and blown clean, ensuring they are ready for immediate installation.
Flexible Installation
The shut-off valves can be equipped with unions to be soldered to the copper piping for seamless integration.
Leak-Tested
Each medical SOV is individually leak-tested before delivery to guarantee reliability.
High-Quality Seals
The ball is sealed with a washer of PTFE, and the stem is sealed with two silicon O-rings or a PTFE washer for superior durability.
Robust Housing Seals
The medical gas shut-off valve housings are sealed with an EPDM quality O-ring, providing an additional layer of protection.
Maintenance-Free
No maintenance required—the ball valve does not need servicing, and when necessary, the whole valve is exchanged.
Compliance Standards
Complies with Medical Devices Directive 93/42/EEC, EN ISO 7396-1 (Central Gas Supply System), and EN 331 (Manually operated ball valves).
Gases | O2, Air, N2, Ar, N2O, CO2 |
---|---|
Material valve housing | Nickel plated brass |
Ball | Chrome plated brass |
Stem | Nickel plated brass |
Max working pressure | 40 bar (4000 kPa) |
Tighten proof | (-1)–50 bar [(-100)–5000 kPa] |
Loading... ... loading table ... |
Item No. | Thread | Valve | L (mm) | H (mm) |
---|---|---|---|---|
325196767 | G1/2" EXT | DN10 | 67 | 46 |
325196768 | G3/4" EXT | DN15 | 77 | 48 |
325197794 | G1" EXT | DN20 | 100 | 52 |
325196770 | G1 1/4" EXT | DN25 | 115 | 54 |
325397236 | G1 1/2" EXT | DN32 | 132 | 72 |
325397237 | G2" EXT | DN40 | 145 | 84 |