The GCE MM90 HP Unit is a semi-automatic gas manifold with a capacity of 90 m3/h, intended to be used in hospital pipeline systems for uninterrupted gas supply.
The GCE MM90 HP Unit gas manifold is designed for use in hospital pipeline systems as a reliable medical gas source. It should be paired with an alarm system to meet standard safety requirements. The semi-automatic medical manifold supplies gas from the operating bank until the cylinders are depleted, then automatically switches to the reserve bank, ensuring continuous gas supply. A stabilizer is recommended for the second stage to maintain consistent pressure and uninterrupted operation.
The Gas Alarm is a standard accessory that provides both visual and audible alerts. It monitors the system and triggers alarms under the following conditions: a change in the operation side, leakage in the reserve side, high operation pressure, or low operation pressure. Additionally, the gas alarm is equipped with relay outputs, allowing it to communicate seamlessly with other equipment in the system, enhancing overall safety and reliability.
The GCE MM90 HP Unit gas manifold is designed for use in hospital pipeline systems as a reliable medical gas source. It should be paired with an alarm system to meet standard safety requirements. The semi-automatic medical manifold supplies gas from the operating bank until the cylinders are depleted, then automatically switches to the reserve bank, ensuring continuous gas supply. A stabilizer is recommended for the second stage to maintain consistent pressure and uninterrupted operation.
The Gas Alarm is a standard accessory that provides both visual and audible alerts. It monitors the system and triggers alarms under the following conditions: a change in the operation side, leakage in the reserve side, high operation pressure, or low operation pressure. Additionally, the gas alarm is equipped with relay outputs, allowing it to communicate seamlessly with other equipment in the system, enhancing overall safety and reliability.
Key Components
MM90 HP Unit gas manifold includes the following components:
Optional Add-Ons
For a complete MM90 HP Unit manifold add:
Regulatory Compliance
Complies with Medical Devices Directive 93/42/EEC
Complies with EN ISO 7396-1 (Central Gas Supply Systems)
Complies with EN 60601-1-2 (Electromagnetic compatibility) present SIS HB 370 and HTM 02-01
Key Components
MM90 HP Unit gas manifold includes the following components:
Optional Add-Ons
For a complete MM90 HP Unit manifold add:
Regulatory Compliance
Complies with Medical Devices Directive 93/42/EEC
Complies with EN ISO 7396-1 (Central Gas Supply Systems)
Complies with EN 60601-1-2 (Electromagnetic compatibility) present SIS HB 370 and HTM 02-01
Gas type(s) | O2, Air, N2, N2O, CO2 |
---|---|
Nominal flow (m3/h) | 90 |
Inlet nominal pressure (BAR) | 200 (20 000 kPa) |
Outlet nominal pressure | 9 bar (setting range 9–15 bar) |
Inlet connection | W21,8×1/14"M |
Outlet connection | G3/4"F + soldering piece pipe ø 22 mm |
Intermediate pressure relieve valve | 16 bar |
Pressure relieve valve pipe dimension | ø 10 mm |
Purge valves connection | W21,8×1/14"M + soldering piece pipe ø 10mm |
Loading... ... loading table ... |
Item No. | Description | Gas | PRV | Signalization |
---|---|---|---|---|
0732314 | MM90 – HP unit 2×1 | O2 | Standard | Alarm TMA6703 |
0732315 | MM90 – HP unit 2×1 | Air | Standard | Alarm TMA6703 |
0732316 | MM90 – HP unit 2×1 | N2O, CO2 | Standard | Alarm TMA6703 |
0732320 | MM90 – HP unit 2×1 | O2, Air | With pull-ring | Alarm TMA9705 |
0732321 | MM90 – HP unit 2×1 | N2O, CO2 | With pull-ring | Alarm TMA9705 |
0727327* | MM90 – HP unit 2×1 | O2, N2O, Air, CO2, N2 | Standard | *basic version without electric sensors |