The GCE MM90 HP Unit is a fully automatic medical gas manifold with a capacity of 90 m3/h that is intended for use in hospital pipeline systems as a medical gas source.
The GCE MM90 HP Unit medical gas manifold is designed to ensure a reliable and continuous gas supply for hospital pipeline systems. It efficiently manages the transfer of gas from the operating bank to the pressure regulator until the cylinders are depleted, at which point it automatically switches to the reserve bank, allowing for seamless gas delivery. The system includes a standard gas alarm that provides both visual and audible alerts for changes in operation, leaks, or pressure deviations, ensuring safety and compliance with medical standards. Additionally, the gas alarm can communicate with other equipment through relays for enhanced monitoring and control.
The GCE MM90 HP Unit medical gas manifold is designed to ensure a reliable and continuous gas supply for hospital pipeline systems. It efficiently manages the transfer of gas from the operating bank to the pressure regulator until the cylinders are depleted, at which point it automatically switches to the reserve bank, allowing for seamless gas delivery. The system includes a standard gas alarm that provides both visual and audible alerts for changes in operation, leaks, or pressure deviations, ensuring safety and compliance with medical standards. Additionally, the gas alarm can communicate with other equipment through relays for enhanced monitoring and control.
Main Components
MM90 includes the following components:
Optional Add-Ons
For a complete MM90 HP Unit manifold add:
Regulatory Compliance
Complies with Medical Devices Directive 93/42/EEC
Complies with EN ISO 7396-1 (Central Gas Supply Systems)
Complies with EN 60601-1-2 (Electromagnetic compatibility)
present SIS HB 370 and HTM 02-01
Main Components
MM90 includes the following components:
Optional Add-Ons
For a complete MM90 HP Unit manifold add:
Regulatory Compliance
Complies with Medical Devices Directive 93/42/EEC
Complies with EN ISO 7396-1 (Central Gas Supply Systems)
Complies with EN 60601-1-2 (Electromagnetic compatibility)
present SIS HB 370 and HTM 02-01
Gas type(s) | O2, Air, N2, N2O, CO2 |
---|---|
Nominal flow (m3/h) | 90 |
Inlet nominal pressure | 200 (20 000 kPa) |
Outlet nominal pressure | 9 bar (setting range 9 – 15 bar) |
Inlet connection | W21,8×1/14"M |
Outlet connection | G1/2"M + soldering piece pipe ø 22 mm |
Intermediate pressure relieve valve | 16 bar |
Pressure relieve valve pipe dimension | ø 10 mm |
Purge valves connection | W21,8×1/14"M + soldering piece pipe ø 10 mm |
Loading... ... loading table ... |
Item No. | Description | Gas | PRV | Signalization |
---|---|---|---|---|
0732322 | MM90 – HP unit AUTO 2×1 | O2 | Standard | Alarm TMA6703 |
0732323 | MM90 – HP unit AUTO 2×1 | Air | Standard | Alarm TMA6703 |
0732324 | MM90 – HP unit AUTO 2×1 | N2O, CO2 | Standard | Alarm TMA6703 |
0727308* | MM90 – HP unit AUTO 2×1 | O2, N2O, Air, CO2, N2 | Standard | *basic version without electric sensors |
0727309 | MM90 – HP unit AUTO 2×1 | O2 | Standard | Pressure switch |
0727310 | MM90 – HP unit AUTO 2×1 | Air | Standard | Pressure switch |
0727311 | MM90 – HP unit AUTO 2×1 | N2O, CO2 | Standard | Pressure switch |