The GCE MM40 Stabilizer is a second-stage pressure reduction unit that equalizes the eventual pressure variation in the hospital pipeline system to ensure accurate pressure from terminal units.
The GCE MM40 Stabilizer serves as a second-stage pressure reduction unit that ensures stable and precise gas delivery in hospital pipeline systems. Paired with high-pressure gas manifolds like the MM40 HP Unit, it maintains consistent gas pressure, even during fluctuations. If pressure deviations occur, alarms are promptly displayed on a gas alarm unit or communicated to central control, ensuring immediate response. The stabilizer can be equipped with a 4–20 mA pressure transmitter or pressure switches. It must be installed according to EN ISO 7396-1 and relevant national standards, ensuring safety and compliance.
The GCE MM40 Stabilizer serves as a second-stage pressure reduction unit that ensures stable and precise gas delivery in hospital pipeline systems. Paired with high-pressure gas manifolds like the MM40 HP Unit, it maintains consistent gas pressure, even during fluctuations. If pressure deviations occur, alarms are promptly displayed on a gas alarm unit or communicated to central control, ensuring immediate response. The stabilizer can be equipped with a 4–20 mA pressure transmitter or pressure switches. It must be installed according to EN ISO 7396-1 and relevant national standards, ensuring safety and compliance.
For a complete MM40 stabilizer manifold add:
For a complete MM40 stabilizer manifold add:
Gases | O2, Air, Air-800, N2, N2O, CO2 |
---|---|
Nominal flow (m3/h) | 40 |
Inlet maximal pressure | 16 (1600 kPa) |
Outlet nominal pressure | 4,5 bar (setting range 0,5–10 bar) |
Inlet connection 1 | G1/2"M + soldering piece pipe ø 12 mm |
Inlet connection 2 | Optional (G1/2"M + soldering piece pipe ø 12 mm) |
Outlet connection | G1/2"M + soldering piece pipe ø 12 mm |
Pressure relieve valve | Optional (6,8 bar; outlet pipe ø 15 mm) |
Pressure sensors | Optional (Pressure switches; Transmitter 4–20 mA) |
Emergency QC inlet | Optional QC by national standards |
Loading... ... loading table ... |
Item No. | Denomination | Gas | PRV | Signalization |
---|---|---|---|---|
0727329 | MM40 – Stabilizer | O2, N2O, Air, CO2, N2 | ||
0727337 | MM40 – Stabilizer | Air–800 | ||
0727332 | MM40 – Stabilizer | O2, N2O, Air, CO2, N2 | With pull-ring | Pressure switch |
0727344 | MM40 – Stabilizer | O2, N2O, Air, CO2, N2 | With pull-ring | 4-20mA |
0727343 | MM40 – Stabilizer | O2 | ||
0727346 | MM40 – Stabilizer | Air | ||
0727347 | MM40 – Stabilizer | Air–800 | ||
0727348 | MM40 – Stabilizer | CO2 | ||
0727364 | MM40 – Stabilizer | N2O |